Hydratec Inc.

AutoCAD Based (Hydracalc)

Total: 87

Page:

* On smaller devices swipe left to view hidden table data

Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
View (card-1100) HydraCALC (AutoCAD Based) None None Unhandled Exception

Component TABCTL32.OCX or one of its dependencies no correctly registered: a file is missing or invalid Unhandled Exception n/a

View (card-661) HydraCALC (AutoCAD Based) Calculate None None

System calculates then reports System is 1.#J over the Water Supply Curve none HydrProg

View (card-659) HydraCALC (AutoCAD Based) None None None

no error or error 13 ediiting aquivalent lengths or all the pipe disappears or file will not open after it was open intially or error or lockup during the process or error or lockup during error check Flexible Connection Flex flexhead

View (card-657) HydraCALC (AutoCAD Based) None None None

User created a new curve for a backflow but it doesn't show up in the list when trying to add it as a fitting. n/a Miscfunc

View (card-656) HydraCALC (AutoCAD Based) Calculate None Runtime Error

When starting a calculation, if the 'Use In the Pre-Calc Questions window, the Darcy-Weisbach Friction Loss Formula' box checked. At the 'Modify K-Factors' window, if the user selects 'No - Modify Existing K-factors for me', you'll get the Run-time Error 11/Division by zero message. run-time error 11 Runtime error 11 n/a

View (card-655) HydraCALC (AutoCAD Based) Calculate Results None

After the calc is complete and the calc result is shown, the last 3 columns will not update nor get filled in, they are left blank. This causes an issue if trying to use Print|Final Unrelated to pumps or gridded systems or fitting curves. three columns blank columns empty columns n/a n/a

View (card-654) HydraCALC (AutoCAD Based) Calculate None Runtime Error

Error 339

View (card-653) HydraCALC (AutoCAD Based) Calculate None None

After running calc most of the right hand columns numbers go to 0. zero blank

View (card-652) HydraCALC (AutoCAD Based) Print Final None Runtime Error

When trying to Print|Final, you get a message saying Run-time error '5': Invalid procedure call or argument runtime 5 run-time 5 run time 5 Run-time error 5 HydraCALC

View (card-651) HydraCALC (AutoCAD Based) Calculate None None

While calculating a job with (i) internal diameters only and (ii)pump AND city water supplies, the user gets an error which says, "Error in MiscFunc.exe|PumpCalc|Form_Activate 62 - Input past end of file" Runtime Error 62 Miscfunc